You are here: Home > Products > SPECIAL APLICATIONS VA series
Products
     

SPECIAL APLICATIONS VA series


Category: FANS Download catalog in pdf format

 Designed for:
- cooling of electronic control panels; 
- ventilation of electrical panels;
- installation in devices in electronics, appliance construction
and automation;
- cooling of welding machines and plasm cutting machines;
- installation in cooling and ventilation systems and air-conditioning devices;
- installation in household air heaters and heat exchangers.

 

Axial fans fall into the following categories:
BA 9/2, BA 12/2, BA 12/2K, BA 14/2, BA 16/2


 
 

The double capsulated ball bearings guarantee 30,000 hours of flawless operation

All fans of this type have a built-in single-phase electric motors with shielded poles and a
short-circuited rotor with double capsulated ball bearings. The fan is square in shape with
internally located fins to which the stator is attached.

The VA series axial fans are suitable to be to fitted to apertures and air conduits with
Ø90, Ø100, Ø120, Ø135 and Ø150.
They can be produce with supply voltages 220V, 115V, 36V or 24V, at frequency of 50Hz or 60Hz.

Isolation class: “H” - 180 degrees Celsius or “L” - 200 degrees Celsius.
Protection degree: IP 44.

Operating conditions:
The fans are designed to operate under normal climatic conditions where the ambient temperature 
can vary from -5 degrees Celsius up to +60 degrees Celsius and a relative humidity
from 40% to 98% at 30 degrees Celsius.
Upon clients’ request the fans can be manufactured to operate at higher temperatures,
in tropical or coastal climatic zones.

Technical Data



┬└ 9/2
Supply voltage Rotational speed Maximum flow rate Maximum static pressure For maximum flow rate Weight  
Consumed power Consumed current  
Hz/V min m3/h Pa W A kg  
50/220 2500 60 50 16 0,095 0,4  
50/220 2500 60 50 15 0,178 0,4  
60/220 3000 67 60 14 0,090 0,4  
 
\"\"\"\" 
_______________________________________________________________________
┬└ 12/2
Supply voltage Rotational speed Maximum flow rate Maximum static pressure For maximum flow rate Weight
Consumed power Consumed current
Hz/V min-1 m3/h Pa W A kg
50/220 2650 150 75 18 0,125 0,8
50/115 2650 150 75 17 0,234 0,8
60/220 3200 180 90 16 0,115 0,8
 
\"\" \"\"
_______________________________________________________________________
┬└ 12/2╩
 
Supply voltage Rotational speed Maximum flow rate Maximum static pressure For maximum flow rate Weight
Consumed power Consumed current
Hz/V min-1 m3/h Pa W A kg
50/220 2650 150 75 18 0,125 0,525
50/115 2650 150 75 17 0,234 0,525
60/220 3200 180 90 16 0,115 0,525
 
\"\" \"\"
_______________________________________________________________________
┬└ 14/2
 
Supply voltage Rotational speed Maximum flow rate Maximum static pressure For maximum flow rate Weight
Consumed power Consumed current
Hz/V min-1 m3/h Pa W A kg
50/220 2650 205 85 42 0,34 1,4
50/115 2650 205 85 42 0,68 1,4
60/220 3200 250 98 38 0,32 1,4
 
\"\" \"\"
_______________________________________________________________________
┬└ 16/2
Supply voltage Rotational speed Maximum flow rate Maximum static pressure For maximum flow rate Weight
Consumed power Consumed current
Hz/V min m3/h Pa W A kg
50/220 2650 240 110 46 0,385 1,2
50/115 2650 240 110 45 0,721 1,2
60/220 3200 290 130 40 0,385 1,2
\"\" \"\"

Pictures

Axial fan
Axial fan
Axial fan type VA 9/2
Axial fan type VA 9/2
Axial fan type VA 12/2K
Axial fan type VA 12/2K
Axial fan type VA 12/2
Axial fan type VA 12/2
Axial fan type VA 14/2
Axial fan type VA 14/2
Axial fan type VA 14/2
Axial fan type VA 14/2
Axial fan type VA 16/2
Axial fan type VA 16/2